Series 600

Description

Barksdale's Series 600 is the ideal solution for applications that require a low cost, accurate, reliable transducer in a small package. Where long term stability is a requirement, the Series 600 transducer delivers. With a robust ceramic sensor that excels in rugged environments, the Series 600 offers high accuracy at 0.5% FSO and thermal stability within .06% over the entire operating range of -40 to 185° F. Wetted materials of 316 stainless steel, ceramic and Viton® make it ideal for use with aggressive media. The Series 600 family is rated NEMA 4X, UL approved and is available in pressure ranges from 0-30 to 0-8700 psig and a variety of standard outputs: 4-20 mA, 0.5-5.5 VDC, 0.5-4.5 VDC ratiometric, 1-11 VDC and 0-10 VDC.

 

Features

  • UL and cUL approved
  • Compact size
  • Stainless steel construction
  • Ceramic sensor technology
  • Current and voltage outputs
  • 0.5% accuracy

Technical specifications

General Specifications*

Accuracy (LH & R): ±0.5% FSO at 75°F (24°C), typical
Typical Life Cycle: 100 million cycles
Proof Pressure: 2 times rated pressure, except -16 and -18 pressure ranges
Input/Excitation Voltage:
625 (2-wire):
623 (3-wire):
624 (3-wire):
626 (3-wire):
627 (3-wire):

9 to 28 VDC
9 to 30 VDC
5 VDC (fixed)
14 to 30 VDC
14 to 30 VDC
Output:
625:



623:



624:



626:



627:

Output: 4 to 20 mA
Full scale output: 16 mA ± 1%
Zero output: 4 mA ± 2%

Output: 0.5 to 5.5 VDC
Full scale output: 5.0 VDC ± 1%
Zero output: 0.5 VDC ± 2%

Output: 0.5 to 4.5 VDC ratiometric
Full scale output: 4.0 VDC ± 2%
Zero output: 0.5 VDC ± 2%

Output: 1 to 11 VDC
Full scale output: 10 VDC ± 1%
Zero output: 1.0 VDC ± 2%

Output: 0 to 10 VDC
Full scale output: 10 VDC ± 1%
Zero output: 0 VDC ± 2%
Supply Current: 15 mA maximum (no load)
Wetted Parts: 316 stainless steel, ceramic and Viton® O-ring (standard)
Enclosure**: NEMA 4X (IP 65)
Pressure Connection: 1/4” NPT standard.
Other options available.
Temperature Ranges:
Operating:
Compensated:
Storage:

-40°F to +185°F (-40°C to +85°C)
30°F to +130°F (-1°C to +54°C)
-40°F to +185°F (-40°C to +85°C)
Temperature Shift:
Zero & Span:

±0.06% FS/K over operating temperature range
Vibration: 15 g’s, 10-2000 Hz, MIL-STD 202
Approval1: cULus UL File E302981, to UL 508, as Industrial Control Equipment (NMTR, NMTR7), and to UL 61010-1, as Process Control Equipment (QUYX, QUYX7).
Shock: 50 g’s, 11 ms, MIL-STD 202 Method 213, Cond. G.
Weight: 5.1 oz (145 grams) (typical)
Warranty: 1 year
1. Conditions of Use: Class 2 power source, Type 4X indoor, 122°F (50°C) max. ambient.

Wiring Code

Electrical Termination Voltage Output Current Output Current Output
H3 H4 / T4 / T5 Series 623/624/626/627 Series 625 Series 625-H4 (-Q21)
Red 1 + Excitation + Excitation Common
Black 2 Common - Excitation Not used
White 3 + Output Not used + Excitation
Drain 4 Case ground Case ground Case ground